The packaging station is where cleaned and inspected instruments are assembled, wrapped, and prepared for steam sterilization or ethylene oxide processing. This critical step requires a workspace that is not only organized and efficient but also free from airborne contaminants that could compromise sterile integrity.
The Haihao series applies the same laminar airflow principles used in operating room ventilation to the packaging environment. By creating a localized clean air zone over the work surface, it significantly reduces the risk of airborne recontamination during the wrapping process. The result is improved sterility assurance, enhanced workflow efficiency, and compliance with international sterile processing standards.
Work Surface: Fabricated from 304 stainless steel with a minimum thickness of 1.2 mm, offering exceptional durability and resistance to corrosion from cleaning agents and sterilants.
Surface Finish: Matte, anti-reflective finish eliminates glare from overhead lighting, reducing eye strain during detailed wrapping tasks.
Seamless Construction: Fully seamless welding with radiused corners eliminates bacterial harborage points and facilitates thorough cleaning and disinfection.
Edge Design: All edges are precision-chamfered to prevent snagging of sterile wraps and protect users from sharp corners.
Optimal Working Height: The work surface is set at a comfortable 850 mm to 900 mm height, accommodating users of various statures in either seated or standing positions.
Generous Work Area: Spacious surface dimensions (customizable, standard 1800 mm × 800 mm) provide ample room for organizing instruments, wraps, and sterilization indicators.
Knee Space Clearance: Open-base design or optional leg recess allows users to stand close to the work surface without obstruction, promoting proper posture during prolonged wrapping sessions.
Under-Counter Cabinetry: Stainless steel cabinets and drawers provide organized storage for wrapping materials, chemical indicators, tape, and documentation.
Adjustable Shelving: Interior shelving can be configured to accommodate supplies of various sizes.
Self-Closing Doors: Cabinet doors feature soft-close mechanisms with tight seals to prevent dust accumulation and maintain a clean environment.
The defining feature of the Haihao Packaging Station is its integrated clean air technology, which creates a ISO Class 5 (Class 100) localized clean zone over the work surface.
HEPA H14 Filtration: The system incorporates a high-efficiency particulate air filter with 99.995% efficiency at 0.3 μm, removing airborne particles, bacteria, and fungi from the work environment.
Vertical Laminar Airflow: Filtered air is directed downward over the work surface in a uniform, unidirectional flow, continuously sweeping away airborne contaminants.
Positive Pressure Protection: The workstation maintains a slight positive pressure relative to the surrounding environment, preventing ingress of unfiltered air during use.
Adjustable Air Velocity: Fan speed can be adjusted to achieve optimal airflow velocity (typically 0.3 m/s to 0.5 m/s) based on user preference and workflow requirements.
Filter Status Monitoring: Built-in differential pressure gauge provides continuous indication of filter condition, alerting users when replacement is needed.
Integrated LED Lighting: Energy-efficient LED light bars are mounted within the laminar flow hood, providing shadow-free illumination of the entire work surface.
Optimal Color Temperature: Lights deliver 5000K to 6000K daylight-color illumination, ensuring accurate color rendering for visual inspection of instruments and chemical indicators.
Flicker-Free Operation: Premium LED drivers eliminate flicker, reducing eye fatigue during extended use.
Adjustable Intensity: Dimming control allows users to customize light levels based on task requirements.
Electrical Outlets: Waterproof GFCI-protected electrical receptacles are conveniently located for powering heat sealers, label printers, and other packaging equipment.
Data Ports: Optional integrated data ports support connectivity for barcode scanners and computer workstations.
Compressed Air Connection: Optional quick-connect fitting for instrument drying or air-powered tools.
The generous work surface can be logically organized to support efficient packaging workflows:
Instrument Inspection Area: Illuminated section for final visual inspection of cleaned instruments.
Wrapping Station: Central work area with ample clearance for manipulating sterilization wraps of various sizes.
Sealing Zone: Dedicated area for heat sealers or tape application.
Labeling Area: Space for applying sterilization indicators and tracking labels.
Peel Pouch Organizer: Integrated rack for organizing peel pouches by size for easy access.
Wrap Dispenser: Optional overhead or under-counter dispenser for sterilization wrap rolls.
Small Parts Trays: Removable stainless steel trays for organizing screws, blades, and other small items during set assembly.
Integrated Disposal Chute: Convenient opening for discarding wrapping trimmings and packaging waste directly into a below-counter receptacle.
Foot-Operated Waste Bin: Optional hands-free waste disposal to maintain sterility of gloved hands.
The SteriWrap™ Packaging Station is designed and manufactured in accordance with international standards for sterile processing and cleanroom equipment:
ISO 14644-1: Capable of maintaining ISO Class 5 (Class 100) air cleanliness in the work zone
ISO 13485: Manufactured under certified quality management systems
AAMI ST79: Comprehensive guide to steam sterilization and sterility assurance in healthcare facilities
GB 50591: Chinese code for cleanroom construction (applicable markets)
CE Certification: Available for European markets
Central Sterile Supply Departments: Instrument set assembly and packaging prior to sterilization
Operating Room Support Areas: Immediate-use packaging for surgical instruments
Ambulatory Surgery Centers: Compact packaging solutions for outpatient facilities
Dental Sterilization Centers: Instrument packaging for dental surgical procedures
Pharmaceutical Compounding: Packaging of sterile compounding supplies
Research Laboratories: Preparation of sterile instruments for animal surgery
Electrical: Standard 220V/50Hz or customized to local specifications
Location: Position away from high-traffic areas and air turbulence sources
Clearance: Minimum 300 mm clearance above and behind unit for maintenance access
Pre-Filter Cleaning: Monthly (washable pre-filter)
HEPA Filter Replacement: Every 12–24 months based on usage and pressure drop readings
Surface Cleaning: Daily with hospital-grade disinfectants compatible with stainless steel
Performance Verification: Annual certification of airflow and particle counts recommended
As manufacturers of operating room equipment, we bring decades of experience in contamination control to the sterile processing environment. The Haihao series is not simply a table with a filter—it is a precision-engineered clean air workstation designed to meet the rigorous demands of hospital sterilization departments.
By providing a localized ISO Class 5 environment for packaging, the station significantly reduces the risk of airborne recontamination between cleaning and sterilization. This added layer of protection contributes to improved patient outcomes and reduced surgical site infection rates.
Thoughtful ergonomic design and integrated utility features streamline the packaging workflow, allowing staff to work more efficiently with less physical strain. Organized storage, dedicated work zones, and integrated equipment support reduce wasted motion and improve productivity.
Constructed from surgical-grade stainless steel with high-quality components, the station is built to withstand decades of use in demanding healthcare environments. The investment in quality construction translates to lower total cost of ownership over the equipment lifecycle.
Designed in accordance with international sterile processing standards, the station provides documentation and performance verification to support regulatory compliance and accreditation requirements.
The SteriWrap™ OR-Grade Packaging Station represents a significant advancement in sterile processing infrastructure. By applying cleanroom technology to the critical task of instrument packaging, it helps healthcare facilities achieve higher levels of sterility assurance while improving workflow efficiency and staff satisfaction.
Whether for a busy central sterile department, an operating room support area, or a specialized processing facility, the SteriWrap™ series offers a solution tailored to your specific requirements. Contact our sterile processing equipment specialists to discuss your needs and discover how the SteriWrap™ Packaging Station can enhance your infection prevention program.